Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (3)
  • Open Access

    ARTICLE

    Minor Pressure Differences within the Fontan-Anastomosis in Patients with Total Cavopulmonary Connection by 4D-Flow Magnetic Resonance Imaging

    Nerejda Shehu1,*, Christian Meierhofer1, Anja Hennemuth2,3, Markus Hüllebrand2,3, Pavlo Yevtushenko3, Peter Ewert1, Stefan Martinoff4, Heiko Stern1

    Congenital Heart Disease, Vol.18, No.4, pp. 461-474, 2023, DOI:10.32604/chd.2023.031075 - 15 September 2023

    Abstract Background: Pressure measurement in total cavopulmonary connection (TCPC) patients is a domain of cardiac catheterization. 4D velocity encoded cardiovascular magnetic resonance (4D–flow MRI) offers an alternative for assessment of even minor pressure differences. The scope of this study was to measure even minor pressure differences in the anastomosis of TCPC patients, who are clinically uncompromised. Methods: Twenty-four patients (median 15 years [8;34]) with TCPC were studied prospectively by 4D-flow MRI. Pressure differences between superior vena cava (SVC) and extracardiac conduit (C) to both right pulmonary artery (RPA) and left pulmonary artery (LPA) were assessed. Small… More > Graphic Abstract

    Minor Pressure Differences within the Fontan-Anastomosis in Patients with Total Cavopulmonary Connection by 4D-Flow Magnetic Resonance Imaging

  • Open Access

    ARTICLE

    Numerical Investigation of an Idealized Total Cavopulmonary Connection Physiology Assisted by the Axial Blood Pump With and Without Diffuser

    Zhenxin Zhao1,#, Tong Chen2,#, Xudong Liu3, Shengzhang Wang2,4,*, Haiyan Lu5,*

    CMES-Computer Modeling in Engineering & Sciences, Vol.125, No.3, pp. 1173-1184, 2020, DOI:10.32604/cmes.2020.013702 - 15 December 2020

    Abstract In order to improve the surgical treatment of the congenital heart disease patient with single ventricle defect, two axial flow blood pumps, one with diffuser and the other without diffuser, were designed and virtually implanted into an idealized total cavopulmonary connection (TCPC) model to form two types of Pump-TCPC physiological structure. Computational fluid dynamics (CFD) simulations were performed to analyze the variations of the hemodynamic characteristics, such as flow field, wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT), between the two Pump-TCPC models. Numerical results indicate that the Pump-TCPC with diffuser More >

  • Open Access

    ARTICLE

    Numerical Analyses of Idealized Total Cavopulmonary Connection Physiologies with Single and Bilateral Superior Vena Cava Assisted by an Axial Blood Pump

    Xudong Liu1, Yunhan Cai1, Bing Jia2, Shengzhang Wang1,*, Guanghong Ding1

    CMES-Computer Modeling in Engineering & Sciences, Vol.116, No.2, pp. 215-228, 2018, DOI:10.31614/cmes.2018.04158

    Abstract Our study evaluated the hemodynamic performance of an axial flow blood pump surgically implanted in idealized total cavopulmonary connection (TCPC) models. This blood pump was designed to augment pressure from the inferior vena cava (IVC) to the pulmonary circulation. Two Fontan procedures with single and bilateral superior vena cava (SVC) were compared to fit the mechanical supported TCPC physiologies. Computational fluid dynamics (CFD) analyses of two Pump-TCPC models were performed in the analyses. Pressure-flow characteristics, energy efficiency, fluid streamlines, hemolysis and thrombosis analyses were implemented. Numerical simulations indicate that the pump produces pressure generations of… More >

Displaying 1-10 on page 1 of 3. Per Page