Louay Abd Al-Azez Mahdi, Mohammed A. Fayad, Miqdam T. Chaichan*
FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.9, pp. 2201-2214, 2023, DOI:10.32604/fdmp.2023.027166
- 16 May 2023
Abstract A theoretical study based on the Penalty factor (PF) method by Cavallini et al. is conducted to show that the pressure drop occurring in a wire-on-tube heat exchanger can be converted into a temperature difference for two types of refrigerants R-134a and R-600a typically used for charging refrigerators and freezers. The following conditions are considered: stratified or stratified-wavy flow condensation occurring inside the smooth tube of a wire-on-tube condenser with diameter 3.25, 4.83, and 6.299 mm, condensation temperatures 35°C, 45°C, and 54.4°C and cover refrigerant mass flow rate spanning the interval from 1 to 7 kg/hr.… More >