chun-chi Li1, chin-chiang Wang2, yin-chia Su2, yu-chen Chu2, chia-chu Weng2
The International Conference on Computational & Experimental Engineering and Sciences, Vol.11, No.2, pp. 31-32, 2009, DOI:10.3970/icces.2009.011.031
Abstract The aim of this paper was to establish the realistic breathing patterns in different exercise conditions by experimental measurement. Generally, the human inhalation rate varies from 15 L/min at rest to 135 L/min for intense exercise and the breathing cycles are varied with different exercise conditions. Previous author have used symmetric Weibel configuration to establish three realistic breathing patterns, i. e., resting (inhalation rate, 15 L/min), light activity (inhalation rate, 30 L/min), and moderate exercise (inhalation rate, 60 L/min). In this study, in addition to reconstructing the three realistic breathing patterns of above mention, we… More >