Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (3)
  • Open Access

    ARTICLE

    Improved Control in Single Phase Inverter Grid-Tied PV System Using Modified PQ Theory

    Nur Fairuz Mohamed Yusof1, Dahaman Ishak2, Muhammad Ammirrul Atiqi Mohd Zainuri3,*, Muhammad Najwan Hamidi2, Zuhair Muhammed Alaas4, Mohamed Mostafa Ramadan Ahmed5

    Intelligent Automation & Soft Computing, Vol.37, No.2, pp. 2441-2457, 2023, DOI:10.32604/iasc.2023.037778 - 21 June 2023

    Abstract Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic (PV) grid-connected systems diversified. This research aims to produce a high-performance inverter with a fast dynamic response for accurate reference tracking and a low total harmonic distortion (THD) even under nonlinear load applications by improving its control scheme. The proposed system is expected to operate in both stand-alone mode and grid-connected mode. In stand-alone mode, the proposed controller supplies power to critical loads, alternatively during grid-connected mode provide excess energy to the utility. A modified variable step incremental conductance (VS-InCond) algorithm is… More >

  • Open Access

    ARTICLE

    An Improvement in Power Quality and By-Product of the Run-Off River Micro Hydro Power Plant

    Ignatius Riyadi Mardiyanto1, Jangkung Raharjo2,*, Sri Utami1, Wahyu Budi Mursanto1, Agoeng Hardjatmo Rahardjo1

    Energy Engineering, Vol.120, No.6, pp. 1295-1305, 2023, DOI:10.32604/ee.2023.027756 - 03 April 2023

    Abstract Utilization of Micro Hydro Power Plant at the Gunung Halu case study type run-off the river is a household use only in the afternoon, around 5 pm until bedtime at about 10 pm. Therefore, more than 75% of the energy is lost. This case study lost power which can be used as a by-product, such as for drying coffee beans. In this case study, a design was carried out to obtain by-products and improve power quality in the electrical system. In addition, they complain about the poor quality of power controlled by frequency using Triac-Based More > Graphic Abstract

    An Improvement in Power Quality and By-Product of the Run-Off River Micro Hydro Power Plant

  • Open Access

    ARTICLE

    Optimized Power Factor Correction for High Speed Switched Reluctance Motor

    R. S. Preethishri*, J. Anitha Roseline, K. Murugesan, M. Senthil Kumaran

    Intelligent Automation & Soft Computing, Vol.35, No.1, pp. 997-1014, 2023, DOI:10.32604/iasc.2023.025510 - 06 June 2022

    Abstract The Power Factor Correction (PFC) in Switched Reluctance (SR) motor is discussed in this article. The SR motors are applicable for multiple applications like electric vehicles, wind mills, machineries etc. The doubly salient structure of SR motor causes the occurrence of torque ripples, which affects the power factor of the motor. To improve the power quality, the power factor has to be corrected and the ripples have to be minimized. In order to achieve these objectives, a novel power factor correction (PFC) method is proposed in this work. Here, the conventional Diode Bridge Rectifier (DBR)… More >

Displaying 1-10 on page 1 of 3. Per Page