Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (3)
  • Open Access

    ARTICLE

    Soft Tissue Feature Tracking Based on Deep Matching Network

    Siyu Lu1, Shan Liu1, Pengfei Hou1, Bo Yang1, Mingzhe Liu2,*, Lirong Yin3, Wenfeng Zheng1,*

    CMES-Computer Modeling in Engineering & Sciences, Vol.136, No.1, pp. 363-379, 2023, DOI:10.32604/cmes.2023.025217 - 05 January 2023

    Abstract Research in the field of medical image is an important part of the medical robot to operate human organs. A medical robot is the intersection of multi-disciplinary research fields, in which medical image is an important direction and has achieved fruitful results. In this paper, a method of soft tissue surface feature tracking based on a depth matching network is proposed. This method is described based on the triangular matching algorithm. First, we construct a self-made sample set for training the depth matching network from the first N frames of speckle matching data obtained by… More > Graphic Abstract

    Soft Tissue Feature Tracking Based on Deep Matching Network

  • Open Access

    ARTICLE

    A Ring-Reinforced Right Ventricle to Pulmonary Artery Conduit is Associated with Better Regional Mechanics after Stage I Norwood Operation

    Benjamin Zielonka1,2,*, David M. Harrild1,2, Sunil J. Ghelani1,2, Eleni G. Elia1,2, Christopher W. Baird3,4, Andrew J. Powell1,2, Rahul H. Rathod1,2

    Congenital Heart Disease, Vol.17, No.5, pp. 591-603, 2022, DOI:10.32604/chd.2022.021509 - 06 September 2022

    Abstract Background: The right ventricle to pulmonary artery conduit (RVPAC) may impair right ventricular (RV) function in patients with functional single right ventricles. Modification of the RVPAC using a ring-reinforced end with dunked insertion into the RV through a limited ventriculotomy may reduce the impact on RV function. We compared RV segmental strain between patients with a traditional RVPAC and ring-reinforced RVPAC using feature tracking cardiovascular magnetic resonance (CMR) imaging. Methods: Patients with CMR examinations after Stage I operation with RVPAC between 2000 and 2018 were reviewed. Ventricular mass, volumes, late gadolinium enhancement (LGE), and peak radial and… More >

  • Open Access

    ARTICLE

    The Impact of a Bicuspid Aortic Valve on Aortic Geometry and Function in Patients with Aortic Coarctation: A Comprehensive CMR Study

    Laura Schweikert1, Dominik Gabbert1, Sylvia Krupickova2, Inga Voges1,*

    Congenital Heart Disease, Vol.16, No.6, pp. 551-560, 2021, DOI:10.32604/CHD.2021.016635 - 08 July 2021

    Abstract Background: An isolated bicuspid aortic valve (BAV) is associated with structural and functional abnormalities of the aorta and the left ventricle (LV). Although ~50% of patients with aortic coarctation (CoA) have a BAV, less is known about its impact on LV function and aortic geometry and function in CoA patients. In this cardiovascular magnetic resonance imaging (CMR) study, we analysed markers of LV and aortic function as well as aortic geometry in a large cohort of CoA patients with a BAV and compared them with CoA patients with a tricuspid aortic valve (TAV). Methods: We included… More >

Displaying 1-10 on page 1 of 3. Per Page