Rachedi Khadraoui1, Latra Boumaraf1,*, Philippe Haberschill2
FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.5, pp. 1115-1128, 2023, DOI:10.32604/fdmp.2022.022674
- 30 November 2022
Abstract A theoretical investigation is presented about a double evaporator ejector refrigeration cycle (DEERC). Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by an internal heat exchanger (IHX). The ejector is introduced into the baseline cycle in order to mitigate the throttling process losses and increase the compressor suction pressure. Moreover, the IHX has the structure of a concentric counter-flow type heat exchanger and is intentionally used to ensure that the fluid at the compressor inlet is vapor. To assess accurately the influence of the IHX on More >
Graphic Abstract