Bin Zhang, Boqiang Wei*
Energy Engineering, Vol.119, No.3, pp. 1197-1218, 2022, DOI:10.32604/ee.2022.018411
- 31 March 2022
Abstract The non-cascade permanent magnet synchronous motor control system has the advantages of simple structure and less adjustable parameters, but the non-cascade structure needs to solve the problem of over-current protection. In this paper, a current constrained control method is used to limit the starting current to a safe range. At the same time, to ensure the robustness and rapidity of the system, a super twist current constraint controller (CCSTA) is generated by combining super twist algorithm (STA) with current constraint control; Considering the diversity of internal and external disturbances, a functional disturbance observer (FDOB) is More >