Suyadi Kartorono*, Herlien Dwiarti Setio, Adang Surahman, Ediansjah Zulkifli
Structural Durability & Health Monitoring, Vol.17, No.3, pp. 195-208, 2023, DOI:10.32604/sdhm.2022.023259
- 25 June 2023
Abstract This paper sums up the determining analysis of the measuring location of Trefl using a thermocouple during the thermography tests. Laboratory temperature distribution testing methods, analysis of value and location of Trefl measurement are explained in this paper. The heat source is two halogen lamps of 500 watts each fitted at a distance of 30–50 cm. Noises appearing during testing of thermography are corrected with measured Trefl value. The results of thermogram correction of corroded concrete surfaces using Trefl values are displayed in this paper too. The concrete surface temperature results of quantitative image processing method are More >