Xiaorui Cheng1,2,*, Xiang Liu1, Boru Lv1
FDMP-Fluid Dynamics & Materials Processing, Vol.18, No.1, pp. 93-107, 2022, DOI:10.32604/fdmp.2022.017566
- 10 November 2021
Abstract An AP1000 nuclear reactor coolant pump is considered to assess the influence of the Impeller/Guide vane clearance on the performances of this type of pumps. Experiments and numerical simulations relying on an unidirectional fluid-solid coupling approach are used to investigate the problem (stress, strain and mode of the rotor). The results reveal the relationship existing between the hydraulic performance of the nuclear reactor coolant pump and the clearance ratio. The effect of clearance ratio on the maximum equivalent stress on the back surface of the impeller blade is greater than that on the working surface More >