Yong Kou1, Ke Jin1, Xiaojing Zheng1,2
CMC-Computers, Materials & Continua, Vol.22, No.2, pp. 129-146, 2011, DOI:10.3970/cmc.2011.022.129
Abstract Magnetic shielding needs to be employed to ensure proper operation of some electronic equipment which are sensitive to external magnetic interference, such as cryogenic valves located inside the ITER feeder cubicles. This paper is concerned with the shielding efficiency of the magnetic shielding enclosures. A 3-D theoretical model for Fe-Ni alloy magnetic shielding enclosures based on finite element method (FEM) is obtained with the nonlinear law of magnetization. The influence of shielding materials, enclosure configurations, single or multi- layer designs, and apertures on the shielding efficiency is investigated. It is shown that the proposed model More >