Xin Qi1,2, Xingtao Shi1, Yingwen Liu1,*
Frontiers in Heat and Mass Transfer, Vol.22, No.6, pp. 1661-1678, 2024, DOI:10.32604/fhmt.2024.058959
- 19 December 2024
Abstract After optimizing the compressor design, condenser tube diameter, and tube row arrangement, air supply volumetric flow rate, and refrigerant charge of the domestic dehumidifier. The optimized design schemes were obtained from the original combinations by non-dominated sorting, and the optimized design schemes were experimentally verified under three environmental conditions according to the test method of T/CAS 342-2020 to obtain a complete idea of dehumidifier multi-component improvement. The results show that the dehumidifying capacity of Scheme 5 is slightly increased by 2.5% at 27°C/60% RH, and its energy factor is significantly increased by 24.6%. When the… More >