Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (3)
  • Open Access

    ARTICLE

    A Stroke-Limitation AMD Control System with Variable Gain and Limited Area for High-Rise Buildings

    Zuo-Hua Li1, Qing-Gui Wu1,*, Jun Teng1,*, Chao-Jun Chen1,2

    CMES-Computer Modeling in Engineering & Sciences, Vol.138, No.1, pp. 865-884, 2024, DOI:10.32604/cmes.2023.029927 - 22 September 2023

    Abstract Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety. An active mass damper (AMD) with stroke limitations is often used to avoid collisions. However, a stroke-limited AMD control system with a fixed limited area shortens the available AMD stroke and leads to significant control power. To solve this problem, the design approach with variable gain and limited area (VGLA) is proposed in this study. First, the boundary of variable-limited areas is calculated based on the real-time status of the moving mass. The variable gain (VG) expression at the More >

  • Open Access

    ARTICLE

    Analysis of the Performances of a New Type of Alumina Nanocomposite Structural Material Designed for the Thermal Insulation of High-Rise Buildings

    Yue Yu*

    FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.3, pp. 697-709, 2023, DOI:10.32604/fdmp.2022.021482 - 29 September 2022

    Abstract The sol-gel method is used to prepare a new nano-alumina aerogel structure and the thermal properties of this nanomaterial are investigated comprehensively using electron microscope scanning, thermal analysis, X-ray and infrared spectrometer analysis methods. It is found that the composite aerogel alumina material has a multi-level porous nano-network structure. When employed for the thermal insulation of high-rise buildings, the alumina nanocomposite aerogel material can lead to effective energy savings in winter. However, it has almost no energy-saving effect on buildings where energy is consumed for cooling in summer. More >

  • Open Access

    ARTICLE

    A “Three-index” Seismic Performance Evaluation Method Based on Sino-US Seismic Code

    Hui Wang1,*, Shuqi Wan2

    Structural Durability & Health Monitoring, Vol.12, No.3, pp. 149-167, 2018, DOI:10.3970/sdhm.2018.03928

    Abstract The Code for Seismic Design of Buildings (GB50011-2010) in 2016 and the method of seismic performance-based design for high-rise buildings in the Guide for Performance-based Design of High-Rise Buildings (TBI2017) are compared. In view of the characteristics and limitations of the seismic performance index set by the Sino-US seismic code, a “three-index” performance index system and evaluation process considering the displacement angle of the structural interlayer, the plastic damage degree of components and the plastic strain of material is put forward; combining the example of time-history analysis of a out-of-code high-rise building under the rare More >

Displaying 1-10 on page 1 of 3. Per Page