Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (4)
  • Open Access

    ARTICLE

    AC-DC Fuzzy Linear Active Disturbance Rejection Control Strategy of Front Stage of Bidirectional Converter Based on V2G

    Guosheng Li1, Qingquan Lv2, Zhenzhen Zhang2, Haiying Dong1,*

    Energy Engineering, Vol.120, No.4, pp. 1045-1065, 2023, DOI:10.32604/ee.2023.023770 - 13 February 2023

    Abstract Aiming at the problems of output voltage fluctuation and current total harmonic distortion (THD) in the front stage totem-pole bridgeless PFC of two-stage V2G (Vehicle to Grid) vehicle-mounted bi-directional converter, a fuzzy linear active disturbance rejection control strategy for V2G front-stage AC-DC power conversion system is proposed. Firstly, the topological working mode of the totem-pole bridgeless PFC is analyzed, and the mathematical model is established. Combined with the system model and the linear active disturbance rejection theory, a double closed-loop controller is designed with the second-order linear active disturbance rejection control as the voltage outer More > Graphic Abstract

    AC-DC Fuzzy Linear Active Disturbance Rejection Control Strategy of Front Stage of Bidirectional Converter Based on V2G

  • Open Access

    ARTICLE

    Optimized Power Factor Correction for High Speed Switched Reluctance Motor

    R. S. Preethishri*, J. Anitha Roseline, K. Murugesan, M. Senthil Kumaran

    Intelligent Automation & Soft Computing, Vol.35, No.1, pp. 997-1014, 2023, DOI:10.32604/iasc.2023.025510 - 06 June 2022

    Abstract The Power Factor Correction (PFC) in Switched Reluctance (SR) motor is discussed in this article. The SR motors are applicable for multiple applications like electric vehicles, wind mills, machineries etc. The doubly salient structure of SR motor causes the occurrence of torque ripples, which affects the power factor of the motor. To improve the power quality, the power factor has to be corrected and the ripples have to be minimized. In order to achieve these objectives, a novel power factor correction (PFC) method is proposed in this work. Here, the conventional Diode Bridge Rectifier (DBR)… More >

  • Open Access

    ARTICLE

    Efficient Single-Stage Bridgeless AC to DC Converter Using Grey Wolf Optimization

    Prema Kandasamy1,*, K. Prem Kumar2

    Computer Systems Science and Engineering, Vol.43, No.2, pp. 487-499, 2022, DOI:10.32604/csse.2022.021693 - 20 April 2022

    Abstract Bridgeless single-stage converters are used for efficient (alternative current) AC-(direct current) DC conversion. These converters control generators, like electromagnetic meso- and micro-scale generators with low voltage. Power factor correction helps increase the factor of the power supply. The main advantage of the power factor is it shapes the input current for increasing the real power of the AC supply. In this paper, a two-switch bridgeless rectifier topology is designed with a power factor correction capability. For the proposed converter topology to have good power quality parameters, the closed loop scheme, which uses the grey wolf… More >

  • Open Access

    ARTICLE

    Efficient Supply Current Control Strategies for Bridgeless Interleaved AC-DC Converter

    R. Sasikala1,*, R. Seyezhai2

    Computer Systems Science and Engineering, Vol.43, No.1, pp. 175-191, 2022, DOI:10.32604/csse.2022.022386 - 23 March 2022

    Abstract This paper presents an efficient supply current wave shaping technique for bridgeless interleaved Single Ended Primary Inductor Converter (SEPIC). The SEPIC converter converts an Alternating Current (AC) to Direct Current (DC) with the boost converter. Power Factor Correction (PFC) is progressively significant to achieve high energy efficiency. The overall system efficiency can be increased as the bridgeless topology has less conduction losses from rectifying bridges. Also, the bridgeless and interleaved techniques are incorporated in this study to achieve better performance. The performance of the system is analyzed on both current control and sensor-less techniques. Different More >

Displaying 1-10 on page 1 of 4. Per Page