Rajen Kumar Nayaka,*
, Ravi Shankar Prasada,†
, Ujjwal Kumar Nayaka, Amit Kumar Guptab
Frontiers in Heat and Mass Transfer, Vol.19, pp. 1-12, 2022, DOI:10.5098/hmt.19.22
Abstract The present experimental work has been carried out for a solar air heater under cross flow condition having inline hole jet plate between bottom plate
and absorber plate with longitudinal fins underside the absorber surface. The performance of this inline hole jet plate solar air heater is compared with
the performance of jet plate solar air heaters without longitudinal fins under cross and non-cross flow conditions for similar geometrical and operational
parameters. Results are presented for mass flow rates of air, ṁ1 = 0.020 - 0.070 kg/sec, ṁ2 = 0.018 - 0.041 kg/sec, flow Reynolds number, Reja2… More >