Influence of Arterial Wall Compliance on the Pressure Drop across Coronary Artery Stenoses under Hyperemic Flow Condition

by Bhaskar Ch,ra Konala∗, Ashish Das∗, Rupak K Banerjee∗, †

Department of Mechanical Engineering, University of Cincinnati, Cincinnati, OH
Department of Mechanical Engineering, 593 Rhodes Hall, ML 0072, University of Cincinnati, Cincinnati, Ohio, 45221. Phone: 513-556-2124; Fax: 513-556-3390; Email: Rupak.Banerjee@uc.edu

Molecular & Cellular Biomechanics 2011, 8(1), 1-20. https://doi.org/10.3970/mcb.2011.008.001

Abstract

Hemodynamic endpoints such as flow and pressure drop are often measured during angioplasty procedures to determine the functional severity of a coronary artery stenosis. There is a lack of knowledge regarding the influence of compliance of the arterial wall-stenosis on the pressure drop under hyperemic flows across coronary lesions. This study evaluates the influence in flow and pressure drop caused by variation in arterial-stenosis compliance for a wide range of stenosis severities. The flow and pressure drop were evaluated for three different severities of stenosis and tested for limiting scenarios of compliant models. The Mooney-Rivlin model defined the non-linear material properties of the arterial wall and the plaque regions. The non-Newtonian Carreau model was used to model the blood flow viscosity. The fluid (blood)-structure (arterial wall) interaction equations were solved numerically using the finite element method. Irrespective of the stenosis severity, the compliant models produced a lower pressure drop than the rigid artery due to compliance of the plaque region. A wide variation in the pressure drop was observed between different compliant models for significant (90% area occlusion) stenosis with 41.0, 32.1, and 29.8 mmHg for the rigid artery, compliant artery with calcified plaque, and compliant artery with smooth muscle cell proliferation, respectively. When compared with the rigid artery for significant stenosis the pressure drop decreased by 27.7% and 37.6% for the calcified plaque and for the smooth muscle cell proliferation case, respectively. These significant variations in pressure drop for the higher stenosis may lead to misinterpretation and misdiagnosis of the stenosis severity.

Keywords


Cite This Article

APA Style
Konala, B.C., Das, A., Banerjee, R.K. (2011). Influence of arterial wall compliance on the pressure drop across coronary artery stenoses under hyperemic flow condition. Molecular & Cellular Biomechanics, 8(1), 1-20. https://doi.org/10.3970/mcb.2011.008.001
Vancouver Style
Konala BC, Das A, Banerjee RK. Influence of arterial wall compliance on the pressure drop across coronary artery stenoses under hyperemic flow condition. Mol Cellular Biomechanics . 2011;8(1):1-20 https://doi.org/10.3970/mcb.2011.008.001
IEEE Style
B.C. Konala, A. Das, and R.K. Banerjee, “Influence of Arterial Wall Compliance on the Pressure Drop across Coronary Artery Stenoses under Hyperemic Flow Condition,” Mol. Cellular Biomechanics , vol. 8, no. 1, pp. 1-20, 2011. https://doi.org/10.3970/mcb.2011.008.001



cc Copyright © 2011 The Author(s). Published by Tech Science Press.
This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • 1709

    View

  • 1203

    Download

  • 0

    Like

Share Link