• Journal Logo

Table of Content

Open Access iconOpen Access

ARTICLE

Interfacial Strength of Cement Lines in Human Cortical Bone

X. Neil Dong1,2, Xiaohui Zhang1, X. Edward Guo1

Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027, U.S.A.
Orthopaedic Research Laboratories, University of California at Davis, Sacramento, CA 95817, U.S.A.

Molecular & Cellular Biomechanics 2005, 2(2), 63-68. https://doi.org/10.3970/mcb.2005.002.063

Abstract

In human cortical bone, cement lines (or reversal lines) separate osteons from the interstitial bone tissue, which consists of remnants of primary lamellar bone or fragments of remodeled osteons. There have been experimental evidences of the cement line involvement in the failure process of bone such as fatigue and damage. However, there are almost no experimental data on interfacial properties of cement lines in human cortical bone. The objective of this study is to design and assemble a precision and computer controlled osteon pushout microtesting system, and to experimentally determine the interfacial strength of cement lines in human cortical bone by performing osteon pushout tests. Thirty specimens were prepared from humeral diaphyses of four human subjects. Twenty specimens were tested under the condition of a small hole in the supporting plate, in which the cement line debonding occurred. The cement line interfacial strength ranged from 5.38 MPa to 10.85 MPa with an average of 7.31±1.73 MPa. On the other hand, ten specimens were tested under the condition of a large hole in the supporting plate, in which the shear failure inside osteons was observed. The specimens tested under the condition of the large hole resulted in an average shear strength of 73.71±15.06 MPa, ranging from 45.97 MPa to 93.74 MPa. Therefore, our results suggest that the cement line interface between osteon and interstitial bone tissue is weaker than that between bone tissue lamellae.

Keywords


Cite This Article

Dong, X. N., Zhang, X., Guo, X. E. (2005). Interfacial Strength of Cement Lines in Human Cortical Bone. Molecular & Cellular Biomechanics, 2(2), 63–68. https://doi.org/10.3970/mcb.2005.002.063



cc This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • 1566

    View

  • 1087

    Download

  • 0

    Like

Related articles

Share Link