Open Access
ABSTRACT
Improved material point method for simulating the zona failure response in piezo-assisted intracytoplasmic sperm injection
The International Conference on Computational & Experimental Engineering and Sciences 2011, 18(2), 59-60. https://doi.org/10.3970/icces.2011.018.059
Abstract
The material point method (MPM), which is an extension from computational fluid dynamics (CFD) to computational solid dynamics (CSD), is improved for the coupled CFD and CSD simulation of the zona failure response in piezo-assisted intracytoplasmic sperm injection (piezo-ICSI). To evaluate the stresses at any zona material point, a plane stress assumption is made in the local tangent plane of the membrane point, and a simple procedure is proposed to find the effective point connectivity for the orientation of the local tangent plane. With an iterative algorithm in each time step, the original MPM is improved to better simulate fluid dynamics problems involving strong shocks. The use of an Eulerian mesh for solving the momentum equations enables the MPM to automatically handle fluid-membrane interactions without requiring the interface-tracking module. Several examples are used to demonstrate the robustness and efficiency of the proposed numerical scheme for simulating three-dimensional fluid-membrane interactions. Finally, the proposed procedure is applied to the shock-induced zona failure analysis for the piezo-ICSI experiment.Cite This Article
APA Style
Gan, Y., Chen, Z., Montgomery-Smith, S. (2011). Improved material point method for simulating the zona failure response in piezo-assisted intracytoplasmic sperm injection. The International Conference on Computational & Experimental Engineering and Sciences, 18(2), 59-60. https://doi.org/10.3970/icces.2011.018.059
Vancouver Style
Gan Y, Chen Z, Montgomery-Smith S. Improved material point method for simulating the zona failure response in piezo-assisted intracytoplasmic sperm injection. Int Conf Comput Exp Eng Sciences . 2011;18(2):59-60 https://doi.org/10.3970/icces.2011.018.059
IEEE Style
Y. Gan, Z. Chen, and S. Montgomery-Smith, “Improved material point method for simulating the zona failure response in piezo-assisted intracytoplasmic sperm injection,” Int. Conf. Comput. Exp. Eng. Sciences , vol. 18, no. 2, pp. 59-60, 2011. https://doi.org/10.3970/icces.2011.018.059
Copyright © 2011 The Author(s). Published by Tech Science Press.
This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.