ARTICLE

crossmark

EFFECT OF EVAPORATOR DIAMETERS ON PERFORMANCES OF A CUSTOM AIR WATER GENERATOR

Mirmanto Mirmantoa,*, Syahrul Syahrula, Agung Tri Wijayantab

a Mechanical Engineering Department, Engineering Faculty, University of Mataram, Jl. Majapahit no. 62, Mataram, NTB, 83125, Indonesia
b Department of Mechanical Engineering, Universitas Sebelas Maret, Jl. Ir. Sutami 36A, Surakarta, 57126, Indonesia
* Corresponding author. Email: mmirmanto@gmail.com

Frontiers in Heat and Mass Transfer 2023, 20, 1-5. https://doi.org/10.5098/hmt.20.9

Abstract

A study to examine the effect of evaporator diameters on the performances of a custom air-water generator had been conducted in naturally room air temperatures. Performances in this study consisted of fresh water production, coefficient of performance, and total heat transfer from the air. The freshwater was attained from the dew that dropped from the evaporator walls. It was from water vapour in the air that condensed due to the low temperature of the evaporator walls. The evaporator which had dimensions of 285 mm x 12.7 mm x 480 mm was placed in an open box (top and bottom). It was made of copper pipes. There were three evaporators tested with different diameters. Case A indicated the diameter of the evaporator was 3.00 mm, Case B was the evaporator with a diameter of 4.00 mm, and Case C was the evaporator with a diameter of 6.35 mm. The results showed that the maximum fresh water obtained was 0.369 kg, the coefficient of performances found ranged from 7.8 to 18.6, and the highest total heat transfer was 152.1 W.

Keywords


Cite This Article

APA Style
Mirmanto, M., Syahrul, S., Wijayanta, A.T. (2023). EFFECT OF EVAPORATOR DIAMETERS ON PERFORMANCES OF A CUSTOM AIR WATER GENERATOR. Frontiers in Heat and Mass Transfer, 20(1), 1-5. https://doi.org/10.5098/hmt.20.9
Vancouver Style
Mirmanto M, Syahrul S, Wijayanta AT. EFFECT OF EVAPORATOR DIAMETERS ON PERFORMANCES OF A CUSTOM AIR WATER GENERATOR. Front Heat Mass Transf. 2023;20(1):1-5 https://doi.org/10.5098/hmt.20.9
IEEE Style
M. Mirmanto, S. Syahrul, and A.T. Wijayanta, “EFFECT OF EVAPORATOR DIAMETERS ON PERFORMANCES OF A CUSTOM AIR WATER GENERATOR,” Front. Heat Mass Transf., vol. 20, no. 1, pp. 1-5, 2023. https://doi.org/10.5098/hmt.20.9



cc Copyright © 2023 The Author(s). Published by Tech Science Press.
This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.