Table of Content

Open Access iconOpen Access

ARTICLE

crossmark

A NUMERICAL AND EXPERIMENTAL STUDY OF THE EFFECT OF USING PERSONAL VENTILATION SYSTEMS ON INDOOR AIR QUALITY IN OFFICE ROOMS

by

Mechanical Engineering Department, University of Babylon, Iraq
* Corresponding author. E-mail: hassan1245konh@gmail.com

Frontiers in Heat and Mass Transfer 2021, 16, 1-15. https://doi.org/10.5098/hmt.16.9

Abstract

In this study, indoor air quality and thermal comfort were investigated for two persons sitting inside an office room of dimensions (3×2.5×2.5m). The office room is equipped with personal ventilation systems positioned 50 cm from the person's face. These systems are characterized by the ability to change the rates of airflow (ATD). Experimental studies and results were conducted on a thermal manikin that simulates the human body in a sitting position, and the results are compared with CFD analysis using the k-epsilon and the RNG turbulent models. The experimental study focused on measuring the speed and temperature of the air in different areas inside the room, as well as measuring it around the thermal manikin and in the breathing zone. In the numerical analysis, the thermal comfort and the indoor air quality and the detailed airflow around the occupants were evaluated using CFD analysis. It has been found that the use of personal ventilation systems increases thermal comfort and indoor air quality. It was found that by maintaining the temperature of the supply air from the personal ventilation system and increasing the speed of the air supply, this leads to a decrease in the temperature of the breathing air, an increase in the quality of the inhaled air, as well as a lowering of the person's temperature.

Keywords


Cite This Article

APA Style
Sahe, H.A., Mahdi, A.A., Al-amir, Q.R. (2021). A NUMERICAL AND EXPERIMENTAL STUDY OF THE EFFECT OF USING PERSONAL VENTILATION SYSTEMS ON INDOOR AIR QUALITY IN OFFICE ROOMS. Frontiers in Heat and Mass Transfer, 16(1), 1-15. https://doi.org/10.5098/hmt.16.9
Vancouver Style
Sahe HA, Mahdi AA, Al-amir QR. A NUMERICAL AND EXPERIMENTAL STUDY OF THE EFFECT OF USING PERSONAL VENTILATION SYSTEMS ON INDOOR AIR QUALITY IN OFFICE ROOMS. Front Heat Mass Transf. 2021;16(1):1-15 https://doi.org/10.5098/hmt.16.9
IEEE Style
H.A. Sahe, A.A. Mahdi, and Q.R. Al-amir, “A NUMERICAL AND EXPERIMENTAL STUDY OF THE EFFECT OF USING PERSONAL VENTILATION SYSTEMS ON INDOOR AIR QUALITY IN OFFICE ROOMS,” Front. Heat Mass Transf., vol. 16, no. 1, pp. 1-15, 2021. https://doi.org/10.5098/hmt.16.9



cc Copyright © 2021 The Author(s). Published by Tech Science Press.
This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • 619

    View

  • 417

    Download

  • 0

    Like

Share Link