Table of Content

Open Access iconOpen Access

ARTICLE

EXPERIMENTAL COOLER BOX PERFORMANCE USING TWO DIFFERENT HEAT REMOVAL UNITS: A HEAT SINK FIN-FAN, AND A DOUBLE FAN HEAT PIPE

by

Mechanical Engineering Department, Engineering Faculty, Mataram University, Mataram, NTB, 83125, Indonesia Jl. Majapahit no. 62, Mataram, NTB, 83125, Indonesia

* Corresponding Author: Email: email

Frontiers in Heat and Mass Transfer 2018, 10, 1-7. https://doi.org/10.5098/hmt.10.34

Abstract

A comparison study of the use of two different heat removal units was conducted to examine the performance of thermoelectric cooler box. The heat removal units employed were a heat sink fin-fan and a double fan heat pipe. Parameters measured as performance indicators are cooling capacity, temperature differences, and COP. In addition, the effect of electrical power on temperature difference and COP was also investigated. The cooler box size is 285 mm x 245 mm x 200 mm and constructed from styrofoam. The results show that there is no difference of the use of a double fan heat pipe or a heat sink fin-fan on the cooler box performances. The Carnot COP decreases with the time, while the experimental COP increases with the time then it is constant after the steady condition has been achieved. Increasing the power decreases the COP but increases the temperature difference.

Keywords


Cite This Article

APA Style
Mirmanto, , Alit, I., Sayoga, I., Sutanto, R., Nurchayati, et al. (2018). EXPERIMENTAL COOLER BOX PERFORMANCE USING TWO DIFFERENT HEAT REMOVAL UNITS: A HEAT SINK FIN-FAN, AND A DOUBLE FAN HEAT PIPE. Frontiers in Heat and Mass Transfer, 10(1), 1-7. https://doi.org/10.5098/hmt.10.34
Vancouver Style
Mirmanto , Alit I, Sayoga I, Sutanto R, Nurchayati , Mulyanto A. EXPERIMENTAL COOLER BOX PERFORMANCE USING TWO DIFFERENT HEAT REMOVAL UNITS: A HEAT SINK FIN-FAN, AND A DOUBLE FAN HEAT PIPE. Front Heat Mass Transf. 2018;10(1):1-7 https://doi.org/10.5098/hmt.10.34
IEEE Style
Mirmanto, I. Alit, I. Sayoga, R. Sutanto, Nurchayati, and A. Mulyanto, “EXPERIMENTAL COOLER BOX PERFORMANCE USING TWO DIFFERENT HEAT REMOVAL UNITS: A HEAT SINK FIN-FAN, AND A DOUBLE FAN HEAT PIPE,” Front. Heat Mass Transf., vol. 10, no. 1, pp. 1-7, 2018. https://doi.org/10.5098/hmt.10.34



cc Copyright © 2018 The Author(s). Published by Tech Science Press.
This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • 665

    View

  • 296

    Download

  • 0

    Like

Share Link