Open Access iconOpen Access

ARTICLE

Fluid-Structure Interaction in Problems of Patient Specific Transcatheter Aortic Valve Implantation with and Without Paravalvular Leakage Complication

Adi Azriff Basri1,6,*, Mohammad Zuber2, Ernnie Illyani Basri1, Muhammad Shukri Zakaria5, Ahmad Fazli Abd Aziz3, Masaaki Tamagawa4, Kamarul Arifin Ahmad1,6

1 Department of Aerospace Engineering, Universiti Putra Malaysia, Serdang, 43400, Malaysia
2 Department of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India
3 Department of Medicine, Universiti Putra Malaysia, Serdang, 43400, Malaysia
4 Department of Biological Function and Engineering, Kyushu Institute of Technology, Kitakyushu, Japan
5 Fakulti Kejuruteraan Mekanikal, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100, Malaysia
6 Aerospace Malaysia Research Center, Universiti Putra Malaysia, Serdang, 43400, Malaysia

* Corresponding Author: Adi Azriff Basri. Email: email

(This article belongs to the Special Issue: Fluid Structure Interaction in Various Engineering Field)

Fluid Dynamics & Materials Processing 2021, 17(3), 531-553. https://doi.org/10.32604/fdmp.2021.010925

Abstract

Paravalvular Leakage (PVL) has been recognized as one of the most dangerous complications in relation to Transcathether Aortic Valve Implantation (TAVI) activities. However, data available in the literature about Fluid Structure Interaction (FSI) for this specific problem are relatively limited. In the present study, the fluid and structure responses of the hemodynamics along the patient aorta model and the aortic wall deformation are studied with the aid of numerical simulation taking into account PVL and 100% TAVI valve opening. In particular, the aorta without valve (AWoV) is assumed as the normal condition, whereas an aorta with TAVI 26 mm for 100% Geometrical Orifice Area (GOA) is considered as the patient aorta with PVL complication. A 3D patient-specific aorta model is elaborated using the MIMICS software. Implantation of the identical TAVI valve of Edward SAPIEN XT 26 (Edwards Lifes ciences, Irvine, California) is considered. An undersized 26 mm TAVI valve with 100% valve opening is selected to mimic the presence of PVL at the aortic annulus. The present research indicates that the existence of PVL can increase the blood velocity, pressure drop and WSS in comparison to normal conditions, thereby paving the way to the development of recirculation flow, thrombus formation, aorta wall collapse, aortic rupture and damage of endothelium.

Keywords


Cite This Article

Basri, A. A., Zuber, M., Basri, E. I., Zakaria, M. S., Fazli, A. et al. (2021). Fluid-Structure Interaction in Problems of Patient Specific Transcatheter Aortic Valve Implantation with and Without Paravalvular Leakage Complication. FDMP-Fluid Dynamics & Materials Processing, 17(3), 531–553. https://doi.org/10.32604/fdmp.2021.010925



cc This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • 2400

    View

  • 1378

    Download

  • 0

    Like

Share Link