Home / Journals / FDMP / Online First / doi:10.32604/fdmp.2024.050773
Special Issues
Table of Content

Open Access

ARTICLE

Simulation Study on the Heat Transfer Characteristics of a Spray-Cooled Single-Pipe Cooling Tower

Kaiyong Hu1,2,*, Zhaoyi Chen1, Yunqing Hu1, Huan Sun1, Zhili Sun1, Tonghua Zou1,3, Jinghong Ning1
1 Tianjin Key Lab of Refrigeration Technology, Department of Refrigeration and Low Temperature Engineering, Tianjin University of Commerce, Tianjin, 300134, China
2 Jiangsu Yongzhiyu Technology Development Co., Ltd., Xuzhou, 221700, China
3 Shandong Onar Refrigeration Technology Co., Ltd., Binzhou, 256600, China
* Corresponding Author: Kaiyong Hu. Email: email
(This article belongs to the Special Issue: Visual digital analysis and optimization in phase change heat transfer processes)

Fluid Dynamics & Materials Processing https://doi.org/10.32604/fdmp.2024.050773

Received 17 February 2024; Accepted 27 May 2024; Published online 25 June 2024

Abstract

The current study focuses on spray cooling applied to the heat exchange components of a cooling tower. An optimization of such processes is attempted by assessing different spray flow rates and droplet sizes. For simplicity, the heat exchanger of the cooling tower is modeled as a horizontal round tube and a cooling tower spray cooling model is developed accordingly using a computational fluid dynamics (CFD) software. The study examines the influence of varying spray flow rates and droplet sizes on the heat flow intensity between the liquid layer on the surface of the cylindrical tube and the surrounding air, taking into account the number of nozzles. It is observed that on increasing the spray flow strength, the heat flow intensity and extent of the liquid film in the system are enhanced accordingly. Moreover, the magnitude of droplet size significantly impacts heat transfer. A larger droplet size decreases evaporation in the air and enhances the deposition of droplets on the round tube. This facilitates the creation of the liquid film and enhances the passage of heat between the liquid film and air. Increasing the number of nozzles, while maintaining a constant spray flow rate, results in a decrease in the flow rate of each individual nozzle. This decrease is not favorable in terms of heat transfer.

Graphical Abstract

Simulation Study on the Heat Transfer Characteristics of a Spray-Cooled Single-Pipe Cooling Tower

Keywords

Spray cooling; droplet sizes; number of nozzles; CFD