Table of Content

Open Access iconOpen Access

ARTICLE

Live broadcast of transcatheter PDA closure in a 700 grams ELBW infant during the International PDA Symposium

Shyam Sathanandam, Ashley Gianinni, Eric Sefton, Kaitlyn Greer, Nathan Stecchi, Kimberly Allen, Ranjit Philip, B. Rush Waller

University of Tennessee Health Science Center, LeBonheur Children’s Hospital, Memphis, Tennessee

* Corresponding Author: Shyam Sathanandam, MD, University of Tennessee Health Science Center, LeBonheur Children’s Hospital, 848 Adams Avenue, Memphis, TN 38103. Email: email

Congenital Heart Disease 2019, 14(1), 85-89. https://doi.org/10.1111/chd.12710

Abstract

Objective: The objective of this article is to describe a live case transmission of tran‐ scatheter closure of a patent ductus arteriosus (PDA) in an extremely low birth weight (ELBW) infant during the first International PDA Symposium conducted in Memphis, Tennessee.
Setting: A multidisciplinary team approach including audiovisual specialists, informa‐ tion technology specialists, physicians, nurses, and other health care specialists was required to perform the transcatheter PDA closure (TCPC) in an ELBW infant at LeBonheur Children’s Hospital and the procedure was broadcast live to the attend‐ ees at the International PDA Symposium allowing for a two‐way audiovisual discus‐ sion during the procedure.
Patient: The patient was a 14 days old 24‐week premature ELBW infant, who weighed 700 g at the time of the procedure. The patient was requiring mechanical ventilation secondary to pulmonary hemorrhage. The PDA measured 4 mm in diameter and 12 mm in length.
Interventions: TCPC was performed safely without any procedural complications using a specialized minimally invasive technique.
Outcome Measures: The patient was weaned off the ventilator in < 7 days after the procedure. The child was discharged 9 weeks after the procedure (35 weeks’ cor‐ rected gestation) weighing 2.2 kg, on full oral feeds and no supplemental oxygen.
Results: The successful TCPC allowed for this child to have an uneventful hospital course. The case also highlights the technical nuances involved in setting up the live transmission.
Conclusions: This case demonstrated to the audience in the International PDA Symposium the feasibility and safety of performing TCPC in an ELBW infant. Live cases are useful in exhibiting the nuances involved in any new technique and allows for best learning experience.

Keywords


Cite This Article

APA Style
Sathanandam, S., Gianinni, A., Sefton, E., Greer, K., Stecchi, N. et al. (2019). Live broadcast of transcatheter PDA closure in a 700 grams ELBW infant during the international PDA symposium. Congenital Heart Disease, 14(1), 85-89. https://doi.org/10.1111/chd.12710
Vancouver Style
Sathanandam S, Gianinni A, Sefton E, Greer K, Stecchi N, Allen K, et al. Live broadcast of transcatheter PDA closure in a 700 grams ELBW infant during the international PDA symposium. Congeni Heart Dis. 2019;14(1):85-89 https://doi.org/10.1111/chd.12710
IEEE Style
S. Sathanandam et al., “Live broadcast of transcatheter PDA closure in a 700 grams ELBW infant during the International PDA Symposium,” Congeni. Heart Dis., vol. 14, no. 1, pp. 85-89, 2019. https://doi.org/10.1111/chd.12710



cc Copyright © 2019 The Author(s). Published by Tech Science Press.
This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • 1576

    View

  • 1235

    Download

  • 0

    Like

Share Link